Author ORCID Identifier

Tien Trung Vu: 0000-0002-3725-2127

Doan Viet Dao: 0000-0002-5586-7993

Abstract

The re-exploitation of coal seams located near the ground is one of the solutions to increase output, reduce mining investment costs, and avoid wasting coal resources. The re-exploitation of coal seams will also cause instability of the surrounding rock mass and may affect surface construction works. Through the process of re-exploiting the longwall in seam H10 at Mong Duong Coal Mine, the authors have studied and evaluated the stability of the rock mass and +30 level surface works (including fan station and gateroad). To achieve the results in this study, the numerical simulation model method and the analytical method were applied. The model analysis results have determined that the displacement and deformation areas of the rock mass around the mining area correspond to the length of the cut in the strike direction of the longwall H10. The analysis and calculation results from the model show that the longwall in seam H10 can be re-exploited when leaving a protective coal pillar about 50 m from the center of the +30 fan station at the east side; this distance ensures the stability of the rock mass that located near the ground and the surface works at +30.

Creative Commons License

Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.

Share

COinS